Wiring and DCC

Reverse Loops and Wyes: Wiring Turnaround Tracks

Learn what reverse loops and wyes are, why they short-circuit two-rail track, and how to wire them with gaps, DPDT switches or DCC auto reversers.

On this page
  1. What a reverse loop and a wye are
  2. Why they cause a short circuit
  3. Wiring a reverse loop
  4. Wiring a wye
  5. Three-rail AC
  6. Loop, wye or turntable?
  7. Testing and common mistakes

What a reverse loop and a wye are

Both are ways to turn a train or locomotive around so it faces the other way.

A reverse loop (also called a balloon loop) is a loop of track that leaves the main line and comes back to it, so a train that enters one way comes out facing the opposite direction. Reverse loops can turn a train of any length that fits on the loop, but they need more room.

A wye is the answer to “what is a wye in railroads?”: three tracks joined in a triangle, with a turnout at each corner. A train can enter one leg, back onto another, and then continue forward, much like a three-point turn in a car. A wye generally takes up less space than a loop, though it needs three turnouts to build and maintain, and it can turn only as much train as fits on the stub tracks. Wyes are also used at junctions so trains can run in either direction.

Why they cause a short circuit

On two-rail track the rails have opposite polarity. In a reverse loop, the rail that was on the left as the train entered ends up on the right as it leaves, so when the loop meets the main line again the two rails of opposite polarity touch. The same thing happens in a wye. A locomotive wheelset crossing that point connects both polarities and causes a short.

The cure is the same for every turnaround track: isolate the section, then arrange for its polarity to match whatever the train is about to enter. Three-rail AC layouts do not have this problem, since the outer rails are common.

Wiring a reverse loop

  1. Make gaps. Cut both rails (or use insulated rail joiners) at each end of the loop, close to where it rejoins the main line. The loop is now an electrically separate section.
  2. Feed the loop. Run feeders to the loop section from a separate pair of wires, not from the main bus.
  3. Reverse the polarity as the train enters. How you do it depends on whether you use DC or DCC.

It is often recommended to make the isolated section at least as long as your longest train so a train doesn’t straddle both gaps, though this isn’t always necessary with an automatic reverser. Keep the gaps as close to the turnouts as practical.

On DC

Use a DPDT (double-pole, double-throw) toggle switch wired as a reversing switch to feed the isolated section. Throw the switch to match the polarity of the track the train is entering, then run on. The usual forum advice is that polarity changes must be made carefully with the train stopped or crawling, or you risk a momentary short.

Some builders automate this with a relay triggered by track occupancy, but a simple toggle is enough for most layouts.

On DCC

Use an auto reverser (also called a reversing module). It watches for a short as a wheel crosses the gap and flips the polarity of the isolated section within a tiny fraction of a second, fast enough that the booster usually doesn’t trip. Several brands make them. Some are wired between the bus and the loop feeders; read your module’s instructions for the exact connections and current rating.

You still need the gaps, and you still need a way for the loop feed to come only through the reverser.

Wiring a wye

A wye is wired like a reverse loop: it contains one polarity reversal that has to be isolated. The simplest approach is to put gaps in both rails at both ends of one leg and feed that leg through a switch or auto reverser. With the leg isolated, you can reverse its polarity to match whichever route the train is taking.

The Spruce Crafts guide suggests an alternative: place the insulated joints at both ends of the same leg so the three tail tracks all share the same polarity. This works well when the wye is part of a junction. Either way, the number and placement of gaps is the only thing that varies from a reverse loop.

Because three turnouts are involved, see turnouts and point motors for model railways for how to throw and wire them. If trains move only one way around the wye, spring-loaded turnouts or an automatic switch decoder can throw the points for you.

Three-rail AC

With three-rail O gauge, you don’t need gaps to avoid a polarity short, but you may want a way to throw turnouts automatically so a train entering a loop doesn’t derail. Forum builders describe non-derailing circuits with an insulated rail section ahead of the turnout, or use ready-made boards such as the Atlas 6924. Check your turnout’s documentation before wiring.

Loop, wye or turntable?

  • A loop turns whole trains and is easy to operate, but takes the most space.
  • A wye turns locomotives and shorter trains in less space and can double as a run-around.
  • A turntable takes the least space but turns one piece of equipment at a time and costs more.

Choose what fits your room and operating plan.

Testing and common mistakes

  • Test with a single locomotive moving slowly before running a long train.
  • Check that both gaps are complete: a partial cut in a rail will not isolate it.
  • Make sure wheel gauge and flangeways on your equipment match the track so wheels don’t bridge the gap and cause a short.
  • Wire the feeds to the loop section only through the reverser or switch.
  • Label which feeders belong to the loop so you can trace faults later.

The overall wiring approach is covered in our model train track wiring guide. If you are unsure where feeders belong around the loop, see DCC track feeders.

The complete guide to wiring and dcc

Model Train Track Wiring: A Complete Guide
Read the guide

Keep exploring